Inclination sensor JN
12
Index Type Value Unit R/W Reset
0x2042 UNSIGNED8 Index for teach values
of the X/Y/Z axes
0: no change
1: set teach, relative
measurement
2: reset teach, absolute
measurement
R/W
0x2043 UNSIGNED8 FIR filter step for angle
measurement
0 : FIR deactivated
1 : FIR lowpass 10Hz
2 : FIR lowpass 5Hz
3 : FIR lowpass 1Hz
4 : FIR lowpass 0�5Hz
R/W
0x2044 UNSIGNED8 Angle calculation
0: perpendicular
1: Euler
2: gimbal 1X
3: gimbal 1Y
R/W
0x2045 UNSIGNED8 CAN 120 Ohm terminating
resistor
0: resistor deactivated
1: resistor activated
R/W
0x2046 UNSIGNED8 Set index for zero of the
X / Y / Z axes
0: no change
1: activate set zero; relative
measurement
2: reset set zero; absolute
measurement
R/W
0x2047 UNSIGNED8 Output value
0: angle
R/W
0x207F UNSIGNED8 Factory reset
1: make factory reset
R/W
8.2.1 Informative (0x2080 – 0x2082)
Index Type Value Unit R/W Reset
0x2080 INTEGER16 Ambient temperature 1/10 °C R
0x2081 INTEGER16 MEMS temperature 1/10 °C R
0x2082 UNSIGNED16 Heating power mW R