Inclination sensor JN
14
Index Type Value Unit R/W Reset
0x2046 UNSIGNED8 Set index for zero of the
X / Y / Z axes
0: no change
1: activate set zero; relative
measurement
2: reset set zero; absolute
measurement
R/W
0x2047 UNSIGNED8 Output value
0: angle
1: v eff (v effective) and a peak
(a peak)
2: aVector X / Y / Z
without DC part
3: aVector X / Y / Z
with DC part
automatic selection of
measuring range ± 2 g
R/W
0x2048 UNSIGNED8 Axis selection
v eff / a peak
X axis active
bit 2 = 1
X axis not active
bit 2 = 0
Y axis active
bit 1 = 1
Y axis not active
bit 1 = 0
Z axis active
bit 0 = 1
Z axis not active
bit 0 = 0
R/W
0x2049 UNSIGNED8 FIR filter step for
v eff / a peak measurement
0 : FIR deactivated
1 : FIR bandpass filter 0�1���1
Hz
2 : FIR bandpass filter 0�1���10
Hz
3 : FIR bandpass filter 1���10 Hz
4 : FIR bandpass filter 2���400
Hz
5 : FIR bandpass filter 10���400
Hz
R/W
0x204A UNSIGNED8 Measuring range for v eff /
a peak measurement and
acceleration
0: ± 2 g
1: ± 4 g
2: ± 8 g
R/W